CJ1W-MD231 DC Input/Transistor Output Unit (24 VDC, 16 Inputs/16 Outputs)

 

Name16-point DC Input/16-point Transistor Output Unit with Fujitsu Connectors (Sinking Outputs)
ModelCJ1W-MD231
Output section (CN1)Input section (CN2)
Rated Voltage12 to 24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
10.2 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.5 A/point, 2.0 A/UnitInput Impedance3.3 kΩ
Maximum Inrush 
Current
4.0 A/point, 10 ms max.Input Current7 mA typical (at 24 VDC)
Leakage Current0.1 mA max.ON Voltage/ON 
Current
14.4 VDC min./3 mA min.
Residual Voltage1.5 V max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
ON Response 
Time
0.1 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
OFF Response 
Time
0.8 ms max.
No. of Circuits16 (16 points/common, 1 circuit)OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
FuseNone
External Power 
Supply
10.2 to 26.4 VDC, 20 mA min.No. of Circuits16 (16 points/common, 
1 circuit)
Number of 
Simultaneously 
ON Points
75% (at 24 VDC)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 130 mA max.
Weight90 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_1_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_1_2
2056_sp_1_3
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_1_4
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both pins A9 and B9 (COM0 (0 
V)) of CN1. 
Be sure to wire both pins A10 and B10 (+V) of 
CN1. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_1_5
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both pins A9 and B9 (COM1) of 
CN2, and set the same polarity for both pins. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

* The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response 
    times are set to 0 ms due to internal element delays.

 

CJ1W-MD233 DC Input/Transistor Output Unit (24 VDC, 16 Inputs/16 Outputs)

 

Name16-point DC Input/16-point Transistor Output Unit with MIL Connectors (Sinking Outputs)
ModelCJ1W-MD233
Output section (CN1)Input section (CN2)
Rated Voltage12 to 24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
10.2 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.5 A/point, 2.0 A/UnitInput Impedance3.3 kΩ
Maximum Inrush 
Current
4.0 A/point, 10 ms max.Input Current7 mA typical (at 24 VDC)
Leakage Current0.1 mA max.ON Voltage/ON 
Current
14.4 VDC min./3 mA min.
Residual Voltage1.5 V max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
ON Response 
Time
0.1 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
OFF Response 
Time
0.8 ms max.
No. of Circuits16 (16 points/common, 1 circuit)OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
FuseNone
External Power 
Supply
10.2 to 26.4 VDC, 20 mA min.No. of Circuits16 (16 points/common, 
1 circuit)
Number of 
Simultaneously 
ON Points
75% (at 24 VDC)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 130 mA max.
Weight90 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_2_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_2_2
2056_sp_2_3
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_2_4
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both terminals 3 and 4 (COM0 
(0 V)) of CN1. 
Be sure to wire both terminals 1 and 2 (+V) of 
CN1. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_2_5
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both pins 3 and 4 (COM1) of 
CN2, and set the same polarity for both pins. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

* The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response 
    times are set to 0 ms due to internal element delays.

 

CJ1W-MD261 DC Input/Transistor Output Unit (24 VDC 32 Inputs/32 Outputs)

 

Name32-point DC Input/32-point Transistor Output Unit with Fujitsu Connectors (Sinking Outputs)
ModelCJ1W-MD261
Output section (CN1)Input section (CN2)
Rated Voltage12 to 24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
10.2 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.3 A/point, 1.6 A/common, 3.2 A/UnitInput Impedance5.6 kΩ
Maximum Inrush 
Current
3.0 A/point, 10 ms max.Input Current4.1 mA typical (at 24 
VDC)
Leakage Current0.1 mA max.ON Voltage/ON 
Current
19.0 VDC min./3 mA 
min. *2
Residual Voltage1.5 V max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
ON Response 
Time
0.5 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *1
OFF Response 
Time
1.0 ms max.
No. of Circuits32 (16 points/common, 2 circuits)OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *1
FuseNone
External Power 
Supply
10.2 to 26.4 VDC, 30 mA min.No. of Circuits32 (16 points/common, 
2 circuits)
Number of 
Simultaneously 
ON Points
75% (24 points) (at 24 
VDC)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current 
of 10 mA max.
Internal Current 
Consumption
5 VDC 140 mA max.
Weight110 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_3_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_3_2
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_3_3
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_3_4
Be sure to wire both terminals A19 and A9 
(COM0 (0 V)) of CN1. 
Be sure to wire both terminals B19 and B9 
(COM1 (0 V)) of CN1. 
Be sure to wire both terminals A20 and A10 (+V) 
of CN1. 
Be sure to wire both terminals B20 and B10 (+V) 
of CN1. 
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_3_5
Be sure to wire both pins A9 and A18 (COM2) of 
CN2, and set the same polarity for both pins. 
Be sure to wire both pins B9 and B18 (COM3) of 
CN2, and set the same polarity for both pins. 
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

*1. The ON response time will be 120 μs maximum and OFF response time will be 400 μs maximum even if the 
       response times are set to 0 ms due to internal element delays. 
*2. Observe the following restrictions when connecting to a 2-wire sensor. 
       • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the 
         sensor (approx. 3 V). 
       • Use a sensor with a minimum load current of 3 mA min. 
       • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

 

CJ1W-MD263 DC Input/Transistor Output Unit (24 VDC 32 Inputs/32 Outputs)

 

Name32-point DC Input/32-point Transistor Output Unit with MIL Connectors (Sinking Outputs)
ModelCJ1W-MD263
Output section (CN1)Input section (CN2)
Rated Voltage12 to 24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
10.2 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.3 A/point, 1.6 A/common, 3.2 A/UnitInput Impedance5.6 kΩ
Maximum Inrush 
Current
3.0 A/point, 10 ms max.Input Current4.1 mA typical (at 24 
VDC)
Leakage Current0.1 mA max.ON Voltage/ON 
Current
19.0 VDC min./3 mA 
min. *2
Residual Voltage1.5 V max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
ON Response 
Time
0.5 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *1
OFF Response 
Time
1.0 ms max.
No. of Circuits32 (16 points/common, 2 circuits)OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *1
FuseNone
External Power 
Supply
10.2 to 26.4 VDC, 30 mA min.No. of Circuits32 (16 points/common, 
2 circuits)
Number of 
Simultaneously 
ON Points
75% (24 points) (at 24 
VDC)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 140 mA max.
Weight110 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_4_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_4_2
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_4_3
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_4_4
Be sure to wire both terminals 23 and 24 
(COM0) of CN1. 
Be sure to wire both terminals 3 and 4 (COM1) 
of CN1. 
Be sure to wire both terminals 21 and 22 (+V) of 
CN1. 
Be sure to wire both terminals 1 and 2 (+V) of 
CN1. 
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_4_5
Be sure to wire both pins 23 and 24 (COM2) of 
CN2, and set the same polarity for both pins. 
Be sure to wire both pins 3 and 4 (COM3) of 
CN2, and set the same polarity for both pins. 
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

*1. The ON response time will be 120 μs maximum and OFF response time will be 400 μs maximum even if the 
       response times are set to 0 ms due to internal element delays. 
*2. Observe the following restrictions when connecting to a 2-wire sensor. 
       • Make sure the input power supply voltage is larger than the ON voltage (19 V) plus the residual voltage of the 
         sensor (approx. 3 V). 
       • Use a sensor with a minimum load current of 3 mA min. 
       • Connect bleeder resistance if you connect a sensor with a minimum load current of 5 mA or higher.

 

CJ1W-MD232 DC Input/Transistor Output Unit (24 VDC, 16 inputs/16 Outputs)

 

Name16-point DC Input/16-point Transistor Output Unit with MIL Connectors (Sourcing Outputs)
ModelCJ1W-MD232
Output section (CN1)Input section (CN2)
Rated Voltage24 VDCRated Input Voltage24 VDC
Operating Load 
Voltage Range
20.4 to 26.4 VDCOperating Input 
Voltage
20.4 to 26.4 VDC
Maximum Load 
Current
0.5 A/point, 2.0 A/UnitInput Impedance3.3 kΩ
Leakage Current0.1 mA max.Input Current7 mA typical (at 24 VDC)
Residual Voltage1.5 V max.ON Voltage/ON 
Current
14.4 VDC min./3 mA min.
ON Response 
Time
0.5 ms max.OFF Voltage/OFF 
Current
5 VDC max./1 mA max.
OFF Response 
Time
1.0 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
Load Short- 
circuit 
Protection
Detection current: 0.7 to 2.5 A min. 
Automatic restart after error clearance.
OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
No. of Circuits16 (16 points/common, 1 circuit)No. of Circuits16 (16 points/common, 
1 circuit)
External Power 
Supply
20.4 to 26.4 VDC, 40 mA min.Number of 
Simultaneously 
ON Points
75% (at 24 VDC)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 130 mA max.
Weight100 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_5_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_5_2
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_5_3
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_5_4
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both terminals 3 and 4 (COM0 
(+V)) of CN1. 
Be sure to wire both terminals 1 and 2 (0 V) of 
CN1. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_5_5
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if polarity is reversed. 
Be sure to wire both pins 3 and 4 (COM1) of 
CN2, and set the same polarity for both pins. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

* The ON response time will be 20 μs maximum and OFF response time will be 400 μs maximum even if the response 
    times are set to 0 ms due to internal element delays.

 

CJ1W-MD563 TTL I/O Unit (32 Inputs/32 Outputs)

 

Name32-point Input /32-point Output TTL I/O Unit with MIL Connectors
ModelCJ1W-MD563
Output section (CN1)Input section (CN2)
Rated Voltage5 VDC±10%Rated Input Voltage5 VDC±10%
Operating Load 
Voltage Range
4.5 to 5.5 VDCInput Impedance1.1 kΩ
Maximum Load 
Current
35 mA/point, 560 mA/common, 1.12 A/UnitInput CurrentApprox. 3.5 mA (at 5 
VDC)
Leakage Current0.1 mA max.ON Voltage3.0 VDC min.
Residual Voltage0.4 V max.OFF Voltage1.0 VDC max.
ON Response 
Time
0.2 ms max.ON Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
OFF Response 
Time
0.3 ms max.OFF Response Time8.0 ms max. (Can be set 
to between 0 and 32 in 
the Setup.) *
No. of Circuits32 points (16 points/common, 2 circuits)
FuseNoneNo. of Circuits32 points (16 points/ 
common, 2 circuits)
External Power 
Supply
5 VDC ± 10%, 40 mA min. 
(1.2 mA × No. of ON points)
Number of 
Simultaneously 
ON Points
100% (16 points/ 
common)
Insulation 
Resistance
20 MΩ min. between the external terminals and the GR terminal (at 100 VDC)
Dielectric 
Strength
1,000 VAC between the external terminals and the GR terminal for 1 minute at a leakage current of 
10 mA max.
Internal Current 
Consumption
5 VDC 190 mA max.
Weight110 g max.
AccessoriesNone
Circuit 
Configuration
CN1 (OUT)CN2 (IN)
2056_sp_6_1
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_6_2
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
External 
connection and 
terminal-device 
variable diagram
CN1 (OUT)CN2 (IN)
2056_sp_6_3
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if the polarity is reversed. 
Be sure to wire both terminals 23 and 24 
(COM0) of CN1. 
Be sure to wire both terminals 3 and 4 (COM1) 
of CN1. 
Be sure to wire both terminals 21 and 22 (+V) of 
CN1. 
Be sure to wire both terminals 1 and 2 (+V) of 
CN1. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.
2056_sp_6_4
When wiring, pay careful attention to the polarity 
of the external power supply. The load may 
operate incorrectly if the polarity is reversed. 
Be sure to wire both pins 23 and 24 (COM2) of 
CN2, and set the same polarity for both pins. 
Be sure to wire both pins 3 and 4 (COM3) of 
CN2, and set the same polarity for both pins. 
The signal names of the terminals are the 
device variable names. 
The device variable names are the names that 
use "Jxx" as the device name.

 

 

* The ON response time will be 120 μs maximum and OFF response time will be 400 μs maximum even if the response 
    times are set to 0 ms due to internal element delays.

 

Bit Allocations for Mixed I/O Unit

32-point Mixed I/O Unit

 

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m 
(Output)
00OUT0/Jxx_Ch1_Out00
01OUT1/Jxx_Ch1_Out01
::
14OUT14/Jxx_Ch1_Out14
15OUT15/Jxx_Ch1_Out15
Wd m+1 
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
14IN14/Jxx_Ch1_In14
15IN15/Jxx_Ch1_In15

 

32-point Mixed I/O Unit

 

Allocated CIO wordSignal name (CJ/NJ)
CIOBit
Wd m 
(Output)
00OUT0/Jxx_Ch1_Out00
01OUT1/Jxx_Ch1_Out01
::
14OUT14/Jxx_Ch1_Out14
15OUT15/Jxx_Ch1_Out15
Wd m+1 
(Output)
00OUT0/Jxx_Ch2_Out00
01OUT1/Jxx_Ch2_Out01
::
14OUT14/Jxx_Ch2_Out14
15OUT15/Jxx_Ch2_Out15
Wd m+2 
(Input)
00IN0/Jxx_Ch1_In00
01IN1/Jxx_Ch1_In01
::
14IN14/Jxx_Ch1_In14
15IN15/Jxx_Ch1_In15
Wd m+3 
(Input)
00IN0/Jxx_Ch2_In00
01IN1/Jxx_Ch2_In01
::
14IN14/Jxx_Ch2_In14
15IN15/Jxx_Ch2_In15


» Do not allow new products at this time.